Selection guide · 2026-11-10
The 3 A or 5 A printed on the datasheet usually refers to one specific combination of single contact, a defined temperature, and all contacts energised. Real use depends on the derating curve: rising ambient temperature, adjacent contacts energised together, and thinner wire all pull the usable current down. A common rule is to design at 70–80% of the rating, then verify with a temperature-rise test.
The difference between 0.1 μm and 0.3 μm of gold is invisible over a few dozen cycles and becomes the difference between passing and failing contact resistance after a few hundred. Interfaces that get serviced often — test fixtures, quick-connect power — deserve a specific look at this number rather than only at price.
First, terminal retention and insertion force: a high-position housing can exceed what the assembly fixture can push when inserted as a block. Second, temperature class: automotive parts are often quoted -40 to 125 °C, but housings within one series do not always share that, so check each substitution individually.
Send positions, pitch, rated current with derating conditions, temperature class, plating thickness and mating cycles together, and we can return a comparable candidate list in one round instead of three.